Wall Bracing

Get Ready: Measure the length of every perimeter wall and the distances between openings and corners to openings for each floor of your plan. Choose a wall bracing method from the code. Determine the percentage of each wall area that needs to be braced, a calculation of wind speed, seismic zone, the level or story, and the chosen method. Multiple methods may apply depending on the design and loads to accommodate.

Let-In Bracing: The old-school choice, made a little easier labor-wise and also a little stronger with metal components versus 1x4 wood, which buckles under force more easily. Set the braces at a 45 degree angle to achieve the best performance. Use this method with rigid foam insulation panels fastened to the outside of the studs to create a thermally broken insulated shell.

Structural Panel Bracing: By far the most common method, it uses 15/16 inch-thick plywood or OSB panels for 16 inch on-center stud spacing (3/8 inch for 24 inch o/c spacing) and extending the full height of the stud wall. The code makes no distinction between vertical or horizontal panel orientation, but high-seismic areas may require more fastener and connector details to comply.

Shear Wall: Shear walls are designed for specific lateral loads (versus prescribed by code) and require an engineer’s stamp of approval. They feature thicker panels and holddowns (at least) at the foundation and are often used for narrow walls, such as on either side of a two-car garage door opening, to comply with the bracing code, and/or in hurricane- or earthquake-prone areas.