DOUBLE JEOPARDY ANSWER KEY

Photo 1

Violation: Lack of fall protection at height above 6 feet.

Standards violated: 1926.501(b)(1), 1926.701(b), 1926.451(g)(1), and 1926.451(e)(1).

Corrective action: Provide standard guardrail protection.

Photo 2

Violation: Lack of fall protection at height above 6 feet.

Standard violated: 1926.501(b)(1).

Corrective action: Provide guardrail system, safety net system, or personal fall arrest system.

Photo 3

Violation: Lack of fall protection.

Standard violated: 1926.501(b)(13).

Corrective action: Provide fall protection (see directive STD 3-0.1A for Group 4).

Photo 4

Violation: Hazard of fall from improper use of forklift.

Standard violated: (5)(a)(1) of the Occupational Safety and Health Act: Hazard of fall while using rough terrain forklift to access roof.

Corrective action: Use ladders or supported scaffolds instead of forklift.

Photo 5

Violation: Unstable scaffolding support.

Standard violated: 1926.451(c)(2).

Corrective action: Provide adequate scaffold support.

Photo 6

Violation: Lack of fall protection.

Standard violated: 1926.501(b)(13).

Corrective action: Provide fall protection (see directive STD 3-0.1A for Group 4).

Photo 7

Violation: Lack of fall protection for employees 10 inches above lower level; no safe access.

Standards violated: 1926.451(g)(1) and 1926.451(e)(1).

Corrective action: Provide competent person to oversee erection of fully planked scaffold platform with a guardrail system and safe access.

Photo 8

Violation: Employee struck by forklift when it fell over.

Standard violated: 1910.178(l)(1)(i).

Corrective action: Train forklift operators to use the vehicle properly, with forks lowered, and how to handle soft soil.

Photo 9

Violation: Cover plate missing on switches (shock hazard).

Standard violated: 1910.305(b)(2).

Corrective action: Replace cover plate.

Photo 10

Violation: Outlet box missing cover, and metal box used as extension cord.

Standard violated: 1910.305(b)(2) and 303(b)(2).

Corrective action: Extension cord taken out of service.

Photo 11

Violation: Failure to crib boom during crane removal (worker crushed).

Standard violated: ANSI B30.5-1968 for truck cranes.

Corrective action: Block or crib boom during disassembly.

Photo 12

Violation: Exposure to silica.

Standards violated: 1910.134(f), 1910.134(e), 1926.55(a), 1926.55(b), and 1926.701(b)

Corrective action: Use a wet cutting process to reduce the amount of respirable silica

dust generated from cutting masonry blocks.

Photo 13:

Violation: Lack of cave-in protection.

Standards violated: CFR 1926.652(a)(1), 1926.651(j)(2), and 1926.100(a)

Corrective action: Provide adequate protection from caveins, such as a trench box, shoring, or sloping. Ensure that employees wear the appropriate head protection (hard hat).

Photo 14

Violation: Lack of cave-in protection.

Standard violated: 1926.652(a)(1).

Corrective action: Provide a trench box or shoring.